$ Electronic data sheet $ for Softstarter PST(B). $ Author: Ove Coman - ABB ATLV AB, Control $ First version date (dd-mm-yyyy): 29-01-2003; Version 01 [File] DescText = "EDS File for Softstarter PST(B), CU 05.05.00"; CreateDate= 29-01-2003; CreateTime= 12:00:00; ModDate = 27-06-2008; ModTime = 10:24:00; Revision = 8.0; [Device] VendCode = 0x2F8; $ Vendor Code VendName = "ABB Stotz Kontakt GmbH"; ProdType = 0xC; $ Product Type ProdTypeStr = "Communications adapter"; ProdCode = 0x2EE1; $ Product Code MajRev = 0x1; $ Major Revision number MinRev = 0x3; $ Minor Revision number ProdName = "Softstarter PST(B)"; $ Product name Catalog = "Catalogue 1"; $ Order number [IO_Info] Default =0x0001; $ Poll connection PollInfo = 0x000D, $ Poll connection can be used with COS or Cyclic I/O. 1, $ Input1 entry is the default input connection. 1; $ Output1 entry is the default output connection. COSInfo= 0x0005, $ COS connection can be used with Polled I/O. 1, $ Input1 entry is the default input connection. 1; $ Output1 entry is the default output connection. CyclicInfo= 0x0009, $ Cyclic connection can be used with Polled I/O. 1, $ Input1 entry is the default input connection. 1; $ Output1 entry is the default output connection. $---Input connections------ Input1= 30, $ 6 Byte bin data, 18 Byte ana data, 6 Byte diagnostics 0, $ All bits are significant 0x0005, $ Poll and COS connection "Input Data", $ Name of Connection 6, $ Path size "20 04 24 07 30 03", $ Assembly Objekt, Inst., Attr. ""; $ Help string $---Output connections------ Output1= 14, $ 2 Bytes bin data, 12 Byte ana data 0, $ All bits are significant 0x0005, $ Poll + COS connection "Binary Output Data", $ Name of connection 6, $ Path size "20 04 24 37 30 03", $ Assembly Objekt, Inst., Attr. "Binary Output 2 Byte binary data"; $ Help string [ParamClass] MaxInst = 65; $ 101 parameters defined Descriptor = 0x01; $ Support individual parameter instances CfgAssembly = 0; $ Not defined [Params] $-----------------------------------------------------------------------------$ Param1 = $ Setting current 0, $ Reserved 6, $ Link Path Size "20 69 24 01 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Setting Ie", $ Parameter Name "A", $ Units String $----Help string -----$ "Setting current", 0, 30000, 1, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param2 = $ Time for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 02 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Ramp", $ Parameter Name "s", $ Units String $----Help string -----$ "Time for Start Ramp", 1, 120, 10, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param3 = $ Time for Stop Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 03 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Stop Ramp", $ Parameter Name "s", $ Units String $----Help string -----$ "Time for Stop Ramp", 0, 120, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param4 = $ Initial Voltage for start ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 04 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Init Volt", $ Parameter Name "%", $ Units String $----Help string -----$ "Initial Voltage for start ramp", 30, 70, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param5 = $ End Voltage for stop ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 05 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "End Volt", $ Parameter Name "%", $ Units String $----Help string -----$ "End Voltage for stop ramp", 30, 70, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param6 = $ Step Down Voltage 0, $ Reserved 6, $ Link Path Size "20 69 24 06 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Step Down", $ Parameter Name "%", $ Units String $----Help string -----$ "Step Down Voltage", 30, 100, 100, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param7 = $ Level of Current Limit 0, $ Reserved 6, $ Link Path Size "20 69 24 07 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Current Lim", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "Level of Current Limit", 15, 70, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param8 = $ Selection of Kick Start 0, $ Reserved 6, $ Link Path Size "20 69 24 08 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Kick Start", $ Parameter Name "", $ Units String $----Help string -----$ "Selection of Kick Start No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param9 = $ Level of Kick Start (if selected) 0, $ Reserved 6, $ Link Path Size "20 69 24 09 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Kick Level", $ Parameter Name "%", $ Units String $----Help string -----$ "Level of Kick Start (if selected)", 50, 100, 50, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param10 = $ Time for Kick Start (if selected) 0, $ Reserved 6, $ Link Path Size "20 69 24 0A 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Kick Time", $ Parameter Name "s", $ Units String $----Help string -----$ "Time for Kick Start (if selected)", 10, 150, 20, $ Min, Max (max enumeration #), and Default values 1, 100, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 2; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param11 = $ Range for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 0B 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Range", $ Parameter Name "", $ Units String $----Help string -----$ "Range for Start Ramp", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param12 = $ Range for Stop Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 0C 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Stop Range", $ Parameter Name "", $ Units String $----Help string -----$ "Selectable Range for Stop Ramp", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param13 = $ Overload protection 0, $ Reserved 6, $ Link Path Size "20 69 24 0D 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Overload", $ Parameter Name "", $ Units String $----Help string -----$ "Overload protection: 0=No, 1=Normal, 2=Dual", 0, 2, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param14 = $ Overload Class 0, $ Reserved 6, $ Link Path Size "20 69 24 0E 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "OL Class", $ Parameter Name "", $ Units String $----Help string -----$ "OL Class S: 0=10A, 1=10, 2=20, 3=30", 0, 3, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param15 = $ Overload Class, Dual Type, Start Class 0, $ Reserved 6, $ Link Path Size "20 69 24 0F 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "OL Class S", $ Parameter Name "", $ Units String $----Help string -----$ "OL Class S: 0=10A, 1=10, 2=20, 3=30, 4=No", 0, 4, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param16 = $ Overload Class, Dual Type, Run Class 0, $ Reserved 6, $ Link Path Size "20 69 24 10 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "OL Class R", $ Parameter Name "", $ Units String $----Help string -----$ "OL Class R: 0=10A, 1=10, 2=20, 3=30, 4=No", 0, 4, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param17 = $ Type of Operation for Overload Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 11 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "OL Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Overload Protection: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param18 = $ Locked Rotor Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 12 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Locked Rotor", $ Parameter Name "", $ Units String $----Help string -----$ "Locked Rotor Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param19 = $ Trip level for Locked Rotor Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 13 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Lock R Lev", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "Trip level for Locked Rotor Protection", 5, 80, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param20 = $ Trip time for Locked Rotor Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 14 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Lock R Time", $ Parameter Name "s", $ Units String $----Help string -----$ "Trip time for Locked Rotor Protection", 2, 100, 10, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param21 = $ Type of Operation for Locked Rotor Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 15 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Lock R Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Locked Rotor Protection: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param22 = $ Underload Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 16 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Underload", $ Parameter Name "", $ Units String $----Help string -----$ "Underload Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param23 = $ Trip Level for Underload Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 17 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Underl Lev", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "Trip level for Underload protection", 4, 8, 5, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param24 = $ Trip time for Underload protection 0, $ Reserved 6, $ Link Path Size "20 69 24 18 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Underl Time", $ Parameter Name "s", $ Units String $----Help string -----$ "Trip time for Underload protection", 1,30,10, $ Min, Max (max enumeration #), and Default values 1,1,1,0, $ Mult, Div, Base, Offset scaling 0,0,0,0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param25 = $ Type Of Operation for Underload Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 19 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Underl Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Underload Protection: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param26 = $ Phase Imbalance Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1A 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Phase Imb", $ Parameter Name "", $ Units String $----Help string -----$ "Phase Imbalance Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param27 = $ Trip Level for Phase Imbalance Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1B 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Ph Imb Lev", $ Parameter Name "%", $ Units String $----Help string -----$ "Trip Level for Phase Imbalance Protection", 10, 80, 80, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param28 = $ Type Of Operation for Phase Imbalance Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1C 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Ph Imb Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Phase Imbalance Prot.: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param29 = $ High Current Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1D 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "High I", $ Parameter Name "", $ Units String $----Help string -----$ "High Current Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param30 = $ Type of Operation for High Current Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1E 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "High I Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for High Current Protection: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param31 = $ Phase Reversal Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 1F 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Phase Rev", $ Parameter Name "", $ Units String $----Help string -----$ "Phase Reversal Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param32 = $ Type of Operation for Phase Reversal Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 20 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Ph Rev Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Phase Reversal Prot.: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param33 = $ PTC Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 21 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "PTC", $ Parameter Name "", $ Units String $----Help string -----$ "PTC Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param34 = $ Type of Operation for PTC Protection 0, $ Reserved 6, $ Link Path Size "20 69 24 22 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "PTC Op", $ Parameter Name "", $ Units String $----Help string -----$ "Type of Operation for PTC Protection: 0=Stop-M, 1=Stop-A, 2=Ind", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param35 = $ An external by-pass contactor is used 0, $ Reserved 6, $ Link Path Size "20 69 24 23 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Ext ByPass", $ Parameter Name "", $ Units String $----Help string -----$ "External By-Pass contactor is used No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param37 = $ High Current Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 24 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Warn I=High", $ Parameter Name "", $ Units String $----Help string -----$ "High Current Warning Protection No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param38 = $ Trip Level for High Current Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 25 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Wa I=H Lev", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "Trip Level for High Current Warning", 5, 80, 12, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param39 = $ Low Current Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 26 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Warn I=Low", $ Parameter Name "", $ Units String $----Help string -----$ "Low Current Warning No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param40 = $ Trip Level for Low Current Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 27 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Wa I=L Lev", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "Trip Level for Low Current Warning", 4, 10, 8, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param41 = $ Overload Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 28 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Warn OL", $ Parameter Name "", $ Units String $----Help string -----$ "Overload Warning No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param42 = $ Trip Level for Overload Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 29 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Wa OL Lev", $ Parameter Name "%", $ Units String $----Help string -----$ "Trip Level for Overload Warning", 40, 99, 90, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param43 = $ Thyristor Overload Warning 0, $ Reserved 6, $ Link Path Size "20 69 24 2A 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Warn SCR OL", $ Parameter Name "", $ Units String $----Help string -----$ "Thyristor Overload Warning No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param44 = $ Type of Operation for Phase Loss Fault 0, $ Reserved 6, $ Link Path Size "20 69 24 2B 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Ph Loss Op", $ Parameter Name "", $ Units String $----Help string -----$ "Type of Operation for Phase Loss Fault: 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param45 = $ Type of Operation for Fieldbus Fault 0, $ Reserved 6, $ Link Path Size "20 69 24 2C 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "FB Fault Op", $ Parameter Name "", $ Units String $----Help string -----$ "Type of Operation for Fieldbus Fault: 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param46 = $ Type of Operation for Frequency Fault 0, $ Reserved 6, $ Link Path Size "20 69 24 2D 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Freq F Op", $ Parameter Name "", $ Units String $----Help string -----$ "Type of Operation for Frequency Fault: 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param47 = $ Type of Operation for Heat sink Overtemperature fault 0, $ Reserved 6, $ Link Path Size "20 69 24 2E 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "HS Temp Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for Heatsink Overtemperature fault: 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param48 = $ Type of Operation for Thyristor Short Circuit fault 0, $ Reserved 6, $ Link Path Size "20 69 24 2F 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "SCR SC Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for SCR SC fault: 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param49 = $ Function of programmable input In0 0, $ Reserved 6, $ Link Path Size "20 69 24 30 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "In0", $ Parameter Name "", $ Units String $----Help string -----$ "0=None, 1=Reset, 2=Enable, 3=Jog, 4=DOL-On, 5=Start2, 6=FB-Dis", 0, 6, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param50 = $ Function of programmable input In1 0, $ Reserved 6, $ Link Path Size "20 69 24 31 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "In1", $ Parameter Name "", $ Units String $----Help string -----$ "0=None, 1=Reset, 2=Enable, 3=Jog, 4=DOL-On, 5=Start3, 6=FB-Dis", 0, 6, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param51 = $ Function of Programmable Relay Output K4 0, $ Reserved 6, $ Link Path Size "20 69 24 32 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Relay K4", $ Parameter Name "", $ Units String $----Help string -----$ "Function of Programmable Relay Output K4: 0=Run, 1=TOR, 2=Event", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param52 = $ Function of Programmable Relay Output K5 0, $ Reserved 6, $ Link Path Size "20 69 24 33 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Relay K5", $ Parameter Name "", $ Units String $----Help string -----$ "Function of Programmable Relay Output K5: 0=Run, 1=TOR, 2=Event", 0, 2, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param53 = $ Function of Programmable Relay Output K6 0, $ Reserved 6, $ Link Path Size "20 69 24 34 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Relay K6", $ Parameter Name "", $ Units String $----Help string -----$ "Function of Programmable Relay Output K6: 0=Run, 1=TOR, 2=Event", 0, 2, 2, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param54 = $ Function of Programmable Software Output V7 0, $ Reserved 6, $ Link Path Size "20 69 24 35 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "SW Outp V7", $ Parameter Name "", $ Units String $----Help string -----$ "Function of Programmable SW Output V7: 0=Run, 1=TOR, 2=Event", 0, 2, 2, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param55 = $ Different events to include for signalling with K4 if Event is selected 0, $ Reserved 6, $ Link Path Size "20 69 24 36 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Event K4", $ Parameter Name "", $ Units String $----Help string -----$ "Events to include for signalling with K4 if Event is selected", 0, 65535, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param56 = $ Different events to include for signalling with K5 if Event is selected 0, $ Reserved 6, $ Link Path Size "20 69 24 37 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Event K5", $ Parameter Name "", $ Units String $----Help string -----$ "Events to include for signalling with K5 if Event is selected", 0, 65535, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param57 = $ Different events to include for signalling with K6 if Event is selected 0, $ Reserved 6, $ Link Path Size "20 69 24 38 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Event K6", $ Parameter Name "", $ Units String $----Help string -----$ "Events to include for signalling with K6 if Event is selected", 0, 65535, 7, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param58 = $ Different events to include for signalling with V7 if Event is selected 0, $ Reserved 6, $ Link Path Size "20 69 24 39 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Event V7", $ Parameter Name "", $ Units String $----Help string -----$ "Events to include for signalling with V7 if Event is selected", 0, 65535, 7, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param59 = $ Control of the softstarter via fieldbus 0, $ Reserved 6, $ Link Path Size "20 69 24 3A 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Fieldb Ctrl", $ Parameter Name "", $ Units String $----Help string -----$ "Control of the softstarter via fieldbus No/Yes", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param60 = $ Type of fieldbus 0, $ Reserved 6, $ Link Path Size "20 69 24 3B 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Fieldb Type", $ Parameter Name "", $ Units String $----Help string -----$ "Type of fieldbus: 0=AS-Int, 1=Other", 0, 1, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param61 = $ Fieldsbus address 0, $ Reserved 6, $ Link Path Size "20 69 24 3C 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Fieldb Addr", $ Parameter Name "", $ Units String $----Help string -----$ "", 0, 1000, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param62 = $ Number of Sequences for Sequence Start 0, $ Reserved 6, $ Link Path Size "20 69 24 3D 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "No Of Seq", $ Parameter Name "", $ Units String $----Help string -----$ "Number of Sequences for Sequence start; 1=No, 2=2, 3=3", 1, 3, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param63 = $ 1st Sequence, Time for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 3E 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Ramp1", $ Parameter Name "s", $ Units String $----Help string -----$ "1st Sequence, Time for Start Ramp", 1, 120, 10, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param64 = $ 1st Sequence, Initial Voltage for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 3F 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Init Volt1", $ Parameter Name "%", $ Units String $----Help string -----$ "1st Sequence, Initial Voltage for Start Ramp", 30, 70, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param65 = $ 1st Sequence, Current Limit 0, $ Reserved 6, $ Link Path Size "20 69 24 40 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Curr Lim1", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "1st Sequence, Current Limit", 15, 70, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param66 = $ 1st Sequence, Setting current 0, $ Reserved 6, $ Link Path Size "20 69 24 41 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "1st Set Ie", $ Parameter Name "A", $ Units String $----Help string -----$ "1st Sequence, Setting current", 0, 30000, 1, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param67 = $ 2nd Sequence, Time for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 42 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Ramp2", $ Parameter Name "s", $ Units String $----Help string -----$ "2nd Sequence, Time for Start Ramp", 1, 120, 10, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param68 = $ 2nd Sequence, Initial Voltage for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 43 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Init Volt2", $ Parameter Name "%", $ Units String $----Help string -----$ "2nd Sequence, Initial Voltage for Start Ramp", 30, 70, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param69 = $ 2nd Sequence, Current Limit 0, $ Reserved 6, $ Link Path Size "20 69 24 44 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Curr Lim2", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "2nd Sequence, Current Limit", 15, 70, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param70 = $ 2nd Sequence, Setting current 0, $ Reserved 6, $ Link Path Size "20 69 24 45 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "2nd Set Ie", $ Parameter Name "A", $ Units String $----Help string -----$ "2nd Sequence, Setting current", 0, 30000, 1, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param71 = $ 3rd Sequence, Time for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 46 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Ramp3", $ Parameter Name "s", $ Units String $----Help string -----$ "3rd Sequence, Time for Start Ramp", 1, 120, 10, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param72 = $ 3rd Sequence, Initial Voltage for Start Ramp 0, $ Reserved 6, $ Link Path Size "20 69 24 47 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Init Volt3", $ Parameter Name "%", $ Units String $----Help string -----$ "3rd Sequence, Initial Voltage for Start Ramp", 30, 70, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param73 = $ 3rd Sequence, Current Limit 0, $ Reserved 6, $ Link Path Size "20 69 24 48 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Curr Lim3", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "3rd Sequence, Current Limit", 15, 70, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param74 = $ 3rd Sequence, Setting current 0, $ Reserved 6, $ Link Path Size "20 69 24 49 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "3rd Set Ie", $ Parameter Name "A", $ Units String $----Help string -----$ "3rd Sequence, Setting current", 0, 30000, 1, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param75 = $ Language to use on display 0, $ Reserved 6, $ Link Path Size "20 69 24 4A 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Language", $ Parameter Name "", $ Units String $----Help string -----$ "Lang: US/UK, FI, SE, PT, NL, IT, FR, ES, DE, CN, RU, TR, PL, CZ", 1, 14, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param79 = $ Type of date presentation 0, $ Reserved 6, $ Link Path Size "20 69 24 4B 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Date Type", $ Parameter Name "", $ Units String $----Help string -----$ "Type of date presentation: 0=ISO, 1=CE, 2=US", 0, 2, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param80 = $ Year 0, $ Reserved 6, $ Link Path Size "20 69 24 4C 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Date Year", $ Parameter Name "", $ Units String $----Help string -----$ "Date Year", 1901, 2038, 2002, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param81 = $ Month 0, $ Reserved 6, $ Link Path Size "20 69 24 4D 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Date Month", $ Parameter Name "", $ Units String $----Help string -----$ "Date Month", 1, 12, 6, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param82 = $ Day 0, $ Reserved 6, $ Link Path Size "20 69 24 4E 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Date Day", $ Parameter Name "", $ Units String $----Help string -----$ "Date Day", 1, 31, 15, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param83 = $ Hour 0, $ Reserved 6, $ Link Path Size "20 69 24 4F 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Time Hour", $ Parameter Name "", $ Units String $----Help string -----$ "Hour", 0, 23, 12, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param84 = $ Minutes 0, $ Reserved 6, $ Link Path Size "20 69 24 50 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Time Min", $ Parameter Name "", $ Units String $----Help string -----$ "Minutes", 0, 59, 30, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param97 = $ ByPass doesn't open operation 0, $ Reserved 6, $ Link Path Size "20 69 24 51 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "BP Closed Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for ByPass doesn't open 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param98 = $ ByPpass doesn't close operation 0, $ Reserved 6, $ Link Path Size "20 69 24 52 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "BP Open Op", $ Parameter Name "", $ Units String $----Help string -----$ "Operation for ByPass doesn't close 0=Stop-M, 1=Stop-A", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param106 = $ PST(B) size 0, $ Reserved 6, $ Link Path Size "20 69 24 53 30 03", $ Link Path to param instance. 0x0010, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "PST(B)", $ Parameter Name "A", $ Units String $----Help string -----$ "PST(B) size", 1, 2500, 100, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param111 = $ C Lim Y Time 0, $ Reserved 6, $ Link Path Size "20 69 24 54 30 03", $ Link Path to param instance 0x0000, $ Support settable path - no LSB $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "C Lim Y Time", $ Parameter Name "s", $ Units String $----Help string -----$ "C Lim Y Time", 0, 120, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param112 = $ C Lim Y Lev 0, $ Reserved 6, $ Link Path Size "20 69 24 55 30 03", $ Link Path to param instance 0x0004, $ Support settable path - no LSB $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "C Lim Y Lev", $ Parameter Name "*Ie", $ Units String $----Help string -----$ "C Lim Y Time", 15, 70, 40, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param113 = $ FB Auto Dis 0, $ Reserved 6, $ Link Path Size "20 69 24 56 30 03", $ Link Path to param instance 0x0012, $ Support settable path - no LSB $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "FB Auto Dis", $ Parameter Name "", $ Units String $----Help string -----$ "FB Auto Dis", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param114 = $ Start Mode 0, $ Reserved 6, $ Link Path Size "20 69 24 57 30 03", $ Link Path to param instance 0x0002, $ Support settable path - no LSB $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Start Mode", $ Parameter Name "", $ Units String $----Help string -----$ "Start Mode", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param115 = $ Stop Mode 0, $ Reserved 6, $ Link Path Size "20 69 24 58 30 03", $ Link Path to param instance 0x0002, $ Support settable path - no LSB $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Stop Mode", $ Parameter Name "", $ Units String $----Help string -----$ "Stop Mode", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param116 = $ Torque Limit 0, $ Reserved 6, $ Link Path Size "20 69 24 59 30 03", $ Link Path to param instance 0x0000, $ Support settable path - no LSB $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Torque Limit", $ Parameter Name "%", $ Units String $----Help string -----$ "Torque Limit", 20, 200, 150, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param117 = $ Tune T-Ctrl 0, $ Reserved 6, $ Link Path Size "20 69 24 5A 30 03", $ Link Path to param instance 0x0000, $ Support settable path - no LSB $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Tune T-Ctrl", $ Parameter Name "%", $ Units String $----Help string -----$ "Tune T-Ctrl", 30, 300, 100, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param123 = $ Analogue Output 0, $ Reserved 6, $ Link Path Size "20 69 24 5B 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Analogue Out", $ Parameter Name "", $ Units String $----Help string -----$ "Analogue Output", 0, 1, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param124 = $ Analogue Reference 0, $ Reserved 6, $ Link Path Size "20 69 24 5C 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Anl Ref", $ Parameter Name "", $ Units String $----Help string -----$ "Analogue Reference", 0, 2, 1, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param125 = $ Analogue Type 0, $ Reserved 6, $ Link Path Size "20 69 24 5D 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Anl Type", $ Parameter Name "", $ Units String $----Help string -----$ "Analogue Type", 0, 8, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param126 = $ I Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 5E 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "I Range Max", $ Parameter Name "A", $ Units String $----Help string -----$ "Analogue Type", 1, 20000, 11000, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param127 = $ U Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 5F 30 03", $ Link Path to param instance. 0x0000, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "U Range Max", $ Parameter Name "V", $ Units String $----Help string -----$ "U Range Max", 10, 1000, 600, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 0; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param128 = $ kW Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 60 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "kW Range Max", $ Parameter Name "kW", $ Units String $----Help string -----$ "kW Range Max", 1, 30000, 15000, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param129 = $ hp Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 61 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "hp Range Max", $ Parameter Name "hp", $ Units String $----Help string -----$ "hp Range Max", 1, 30000, 15000, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param130 = $ Q Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 62 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Q Range Max", $ Parameter Name "kVAr", $ Units String $----Help string -----$ "Q Range Max", 1, 30000, 15000, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param131 = $ S Range Max 0, $ Reserved 6, $ Link Path Size "20 69 24 63 30 03", $ Link Path to param instance. 0x0004, $ Support settable path - no $ Support enumarated strings - no $ Support scaling - yes $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "S Range Max", $ Parameter Name "kVA", $ Units String $----Help string -----$ "S Range Max", 1, 30000, 15000, $ Min, Max (max enumeration #), and Default values 1, 10, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param132 = $ Imitate SW 0, $ Reserved 6, $ Link Path Size "20 69 24 64 30 03", $ Link Path to param instance. 0x0012, $ Support settable path - no $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - yes $ Support real time update - no $ Support extended scaling - no 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Imitate SW", $ Parameter Name "", $ Units String $----Help string -----$ "Imitate SW", 0, 9, 9, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ Param133 = $ Connection 0, $ Reserved 6, $ Link Path Size "20 69 24 64 30 03", $ Link Path to param instance. 0x0002, $ Support settable path - no LSB $ Support enumarated strings - yes $ Support scaling - no $ Support scaling links - no $ Read only parameter - no $ Support real time update - no $ Support extended scaling - no MSB 9, $ Data Type - double unsigned int 4, $ Data Size - (in bytes) "Connection", $ Parameter Name "", $ Units String $----Help string -----$ "Connection", 0, 3, 0, $ Min, Max (max enumeration #), and Default values 1, 1, 1, 0, $ Mult, Div, Base, Offset scaling 0, 0, 0, 0, $ Mult, Div, Base, Offset links - not used 1; $ Decimal places $-------------------------------------------------------------------------------------------------------------------------$ [EnumPar] Param8 = "No", "Yes"; Param11 = "1-30s", "1-120s"; Param12 = "0-30s", "0-120s"; Param13 = "No", "Normal", "Dual"; Param14 = "10A", "10", "20", "30"; Param15 = "No", "10A", "10", "20", "30"; Param16 = "No", "10A", "10", "20", "30"; Param17 = "Stop-M", "Stop-A", "Ind"; Param18 = "No", "Yes"; Param21 = "Stop-M", "Stop-A", "Ind"; Param22 = "No", "Yes"; Param25 = "Stop-M", "Stop-A", "Ind"; Param26 = "No", "Yes"; Param28 = "Stop-M", "Stop-A", "Ind"; Param29 = "No", "Yes"; Param30 = "Stop-M", "Stop-A", "Ind"; Param31 = "No", "Yes"; Param32 = "Stop-M", "Stop-A", "Ind"; Param33 = "No", "Yes"; Param34 = "Stop-M", "Stop-A", "Ind"; Param35 = "No", "Yes"; Param37 = "No", "Yes"; Param39 = "No", "Yes"; Param41 = "No", "Yes"; Param43 = "No", "Yes"; Param44 = "Stop-M", "Stop-A"; Param45 = "Stop-M", "Stop-A"; Param46 = "Stop-M", "Stop-A"; Param47 = "Stop-M", "Stop-A"; Param48 = "Stop-M", "Stop-A"; Param49 = "None", "Reset", "Enable", "Jog", "DOL-On", "Start2", "FB-Dis"; Param50 = "None", "Reset", "Enable", "Jog", "DOL-On", "Start3", "FB-Dis"; Param51 = "Run", "TOR", "Event"; Param52 = "Run", "TOR", "Event"; Param53 = "Run", "TOR", "Event"; Param54 = "Run", "TOR", "Event"; Param59 = "No", "Yes"; Param60 = "AS-Int", "Other"; Param62 = "No", "2", "3"; Param75 = "US/UK", "FI", "SE", "PT", "NL", "IT", "FR", "ES", "DE", "CN", "RU", "TR", "PL", "CZ"; Param79 = "ISO", "CE", "US"; Param97 = "Stop-M", "Stop-A"; Param98 = "Stop-M", "Stop-A"; Param113 = "No", "Yes"; Param114 = "Volt", "Torque"; Param115 = "Volt", "Torque"; Param123 = "No", "Yes"; Param124 = "0-20mA", "4-20mA", "0-10V"; Param125 = "I Amp", "U Volt", "P kW", "P hp", "Q kVAr", "S kVA", "TmpMot", "TmpSCR", "cosPhi"; Param132 = "010000", "010100", "020001", "030302", "030401", "030500", "040002", "050202", "050404", "050500"; Param133 = "Auto", "Line", "DeltaUI", "DeltaIU"; [Groups] Group1 = "Motor data", 1, 1; Group2 = "Ramp settings", 7, 2, 3, 4, 5, 6, 11, 12; Group3 = "Current Limit", 2, 1, 7; Group4 = "Kick start Parameters", 3, 8, 9, 10; Group5 = "Overload Protection", 5, 13, 14, 15, 16, 17; Group6 = "Locked Rotor Protection", 4, 18, 19, 20, 21; Group7 = "Underload Protection", 4, 22, 23, 24, 25; Group8 = "Phase Imballance Protection", 3, 26, 27, 28; Group9 = "High Current Protection", 2, 29, 30; Group10 = "Phase Reversal protection", 2, 31, 32; Group11 = "PTC Protection", 2, 33, 34; Group12 = "ByPass", 3, 35, 97, 98; Group13 = "Warnings", 7, 37, 38, 39, 40, 41, 42, 43; Group14 = "Operation at faults", 7, 44, 45, 46, 47, 48, 97, 98; Group15 = "Programmable inputs", 2, 49, 50; Group16 = "Output Relay Operation", 8, 51, 52, 53, 54, 55, 56, 57, 58; Group17 = "Fieldbus control", 5, 59, 60, 61, 113, 132; Group18 = "Sequence Start", 13, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74; Group19 = "Date and Time", 5, 80, 81, 82, 83, 84; Group20 = "Read Only", 10, 75, 79, 80, 81, 82, 83, 84, 106, 113, 132; Group21 = "Special Settings", 2, 111, 112; Group22 = "Torque Control", 4, 114, 115, 116, 117; Group23 = "Analogue Output", 9, 123, 124, 125, 126, 127, 128, 129, 130, 131; $------Input connections-----$ $ $Word Byte Bit Data Description $-----------------------------------------------------------------------------------$ $ 1 0 0 K4 relay output Status of K4 $ 1 K5 relay output Status of K5 $ 2 K6 relay output Status of K6 $ 3 V7 Progr soft out Status of V7 $ 4 Start Input Status of Start Input $ 5 Stop Input Status of Stop Input $ 6 In0 Input Status of In0 $ 7 In1 Input Status of In1 $ 1 0(8) Run Run Status $ 1(9) Top Of Ramp Top Of Ramp Status $ 2(10) Line or Delta conn 0 = Line, 1 = Delta $ 3(11) Phase sequence 0 = L1,L2,L3 1=L1,L3,L2 $ 4(12) Prot Motor OL Event Status $ 5(13) Prot Locked Rot Event Status $ 6(14) Prot Underload Event Status $ 7(15) Prot Phase Imb Event Status $ 2 2 0 Prot High I Event Status $ 1 Prot Phase Rev Event Status $ 2 Prot PTC Event Status $ 3 Fault ByPass Event Status, OBSOLETE! $ 4 Prot SCR OL Event Status $ 5 Warn OL Event Status $ 6 Warn SCR OL Event Status $ 7 Warn I=High Event Status $ 3 0(8) Warn I=Low Event Status $ 1(9) Fault (gen sign) Event Status, general for all faults $ 2(10) Fault Phase Loss Event Status $ 3(11) Fault SC SCR Event Status $ 4(12) Fault Open SCR Event Status $ 5(13) Fault Wrong Freq Event Status $ 6(14) Fault Connection Event Status $ 7(15) Fault Internal Event Status $ 3 4 0 Fault FB Timeout Event Status $ 1 Fault HS Temp Event Status $ 2 Fault Line side Event Status $ 3 Fault BP Closed Event Status $ 4 Fault BP Open Event Status $ 5 (Warn SC SCR Event Status, Not used, changed to dummy/spare again) $ 6 Shunt Fault Event Status, general for faults that cannot stop the motor $ 7 Fault Line/Delta Event Status $ 5 0(8) Local Control Set when in Local Control mode (keypad control) $ 1(9) Start OK Set when the PST believes it can start without tripping for fault $ 2(10) Spare (Vaule = 0) $ 3(11) Spare (Vaule = 0) $ 4(12) Spare (Vaule = 0) $ 5(13) Spare (Vaule = 0) $ 6(14) Spare (Vaule = 0) $ 7(15) Spare (Vaule = 0) $-----------------------------------------------------------------------------------$ $ 4 6 and 7 Phase current L1 Value =1000 >>> 1000A $ 5 8 and 9 Phase current L2 Value =1000 >>> 1000A $ 6 10 and 11 Phase current L3 Value =1000 >>> 1000A $ 7 12 and 13 Max phase current Value =1000 >>> 1000A $ 8 14 and 15 Measured frequency Value =100 >>>> 100Hz $ 9 16 and 17 Output voltage Value =100 >>>> 100% $ 10 18 and 19 Calc. Motor temp. Value =100 >>>> 100% $ 11 20 and 21 Count. no of Starts Value =100 >>>> 10000 times $ 12 22 and 23 Run Time Value =100 >>>> 1000 hours $-----------------------------------------------------------------------------------$ $ 13 24 Channel number 1 Parameter number $ 25 Error code 1 Parameter value out of range $ 14 26 Channel number 2 Parameter number $ 27 Error code 2 Parameter number out of range $ 15 28 Channel number 3 Parameter number $ 29 Error code 3 Parameter setting when fieldbus control is disabled $-----------------------------------------------------------------------------------$ $------Output connections-----$ $ $Word Byte Bit Data Description $-----------------------------------------------------------------------------------$ $ 1 0 0 Start (1st Seq.) Start1 if sequence start. $ 1 Stop Stop when signal is negated. $ 2 Reset Events Reset - possible events. $ 3 Enable Enable, to be set for run. $ 4 Jog Jog when signal is set. $ 5 DOL start DOL start when signal is set. $ 6 Start2 (2nd Seq.) Start2 if sequence start. $ 7 Start3 (3rd Seq.) Start3 if sequence start. $ 1 0 Time sync. $ 1 Reset diagnostics Reset the fieldbus diagostic area $ 2 Spare $ 3 Spare $ 4 Spare $ 5 Spare $ 6 Spare $ 7 Spare $-----------------------------------------------------------------------------------$ $ 2 2 and 3 Year Value = 2002 >>> Year 2002 $ 3 4 and 5 Month Value = 12 >>> December $ 4 6 and 7 Day Value = 31 >>> 31st $ 5 8 and 9 Hour Value = 23 >>> 23 h $ 6 10 and 11 Minutes Value = 59 >>> 59 min $ 7 12 and 13 Seconds Value = 59 >>> 59 sec $-----------------------------------------------------------------------------------$